Schedule service(631) 655-8120Energy Kinetics · System 2000 Frontier · EK1F and EK2F
A low-mass oil boiler with its own hot water storage, made for large homes with baseboard or radiant heat. Specs, sizing and installation in The Hamptons and across Suffolk County.

88.6%top AFUE rating
B100Bioheat listed
5 zonesstandard, up to 15
Ratings change with the oil firing rate. The highest ratings need a sidewall vent; with a chimney the best is 87.5% (EK1F) or 87.6% (EK2F).
Is it right for your home?
System 2000 is a combined heating and hot water system. Its low-mass boiler heats up in about 90 seconds, and its Energy Manager sends leftover heat to a zone or the hot water tank after each cycle instead of losing it up the chimney.
We size every boiler with a heat loss calculation, not by matching the old one.
How it works
Its low-mass design reaches 140°F in about 90 seconds, so it does not keep a large mass of water hot all day.
It controls 4 heating zones and the hot water tank as standard.
When a call for heat ends, the burner stops but the pump keeps running, sending the remaining heat to the last zone or the hot water tank.
Full specifications
Figures from Energy Kinetics' September 2026 brochure and EK1/EK2 oil installation manual. Ratings change with the oil firing rate we set for your home.
| EK1F | EK2F | |
|---|---|---|
| Capacity | ||
| Oil firing rate | 0.68 to 1.00 GPH | 1.20 to 1.75 GPH |
| Heating capacity (DOE) | 82,000 to 118,000 BTU/h | 149,000 to 207,000 BTU/h |
| Factory setting | 0.85 GPH · 102,000 BTU/h | 1.40 GPH · 170,000 BTU/h |
| Efficiency | ||
| AFUE (by firing rate) | 86.6% to 88.6% | 86.4% to 88.4% |
| AFUE at factory setting | 87.5% | 87.6% |
| Best AFUE with a chimney | 87.5% | 87.6% |
| Listings | ENERGY STAR certified (EK1F from 0.85 GPH) | |
| Hot water | ||
| Hot water in the first hour (40-gal tank) | 155 to 205 gal | 270 to 375 gal |
| Storage tank options | 40, 80 or 120 gallons, glass-lined | |
| Installation | ||
| Fuel | Oil, or Bioheat up to B100 with a B100-listed burner | |
| Venting | Chimney or sidewall power vent, depending on firing rate; the most efficient settings vent through a side wall | |
| Flue outlet | 4" | 6" |
| Zones | 5 standard (4 heating, 1 hot water), up to 15 | |
| Electrical | 120 V, 60 Hz, 7.5 A on a 15 A circuit | |
| Width and height | 24" wide · 48" tall on low base, 56" on standard base | |
| Depth without burner | 41" | 49" |
| Burner | 8" to 13" of extra depth, by burner | |
| Weight with stand and piping | 350 lb | 475 lb |
Installed price
Two homes with the same equipment can have very different projects. We visit, check your chimney, zones and hot water use, and run a heat loss calculation, then give you one written quote that covers everything.
Tank condition, filters and fuel lines rated for the Bioheat blend you burn.
Chimney liner size, or a sidewall power vent depending on the firing rate.
Number of heating zones and how the boiler ties into your baseboard or radiant piping.
40, 80 or 120 gallons, based on baths, guests and soaking tubs.
Disconnecting, draining and hauling away the old system.
Town permits and fuel safety checks.
There are no PSEG Long Island or federal rebates for oil boilers in 2026; the federal 25C credit ended for equipment installed after December 31, 2025. New York requires Bioheat in heating oil, B10 today and B20 from July 2030, and System 2000 is UL listed for blends up to B100.
If you are open to switching fuels, cold-climate heat pumps may qualify for PSEG Long Island rebates. We can quote both options so you can compare.
Why install it with Hamptons Air
Energy Kinetics gives the boiler's pressure vessel a lifetime limited warranty, and every new installation includes our Gold Membership.
We size the equipment to your home, not to the old unit, which is often oversized.
We match the burner and filtration to the blend your oil company delivers.
Locations in Quogue and Eastport, serving homes from Westhampton to Montauk and across Suffolk County.
Questions homeowners ask
It depends on your heat loss and hot water use. The EK1F covers 82,000 to 118,000 BTU/h of heating and the EK2F 149,000 to 207,000 BTU/h; Energy Kinetics designs the EK2F for large homes. We size it with a heat loss calculation.
AFUE ratings run from 86.4% to 88.6% depending on the firing rate. The top settings need a sidewall vent; with a chimney the best is 87.5% to 87.6%. ENERGY STAR lists the EK1F from 0.85 GPH and the EK2F. Energy Kinetics says its heat recovery saves more than the rating shows; actual savings depend on your home.
Yes. It is UL listed for oil blends up to B100 biodiesel with a B100-listed burner. New York requires B10 in heating oil today and B20 from July 2030.
With a 40-gallon tank, Energy Kinetics rates it from 155 gallons in the first hour on the smallest EK1F setting to 375 gallons on the largest EK2F setting; figures above 195 gallons assume a continuous draw. Tanks also come in 80 and 120 gallons.
Usually, through a lined masonry or stainless chimney. Some firing rates are approved only for a sidewall power vent, so we choose the firing rate and the venting together.
Not from PSEG Long Island or the federal government in 2026; the federal 25C credit ended for equipment installed after December 31, 2025. Heat pumps may qualify for PSEG Long Island rebates if you are open to switching.
Energy Kinetics gives the pressure vessel a lifetime limited warranty, prorated after year 10 and transferable to a new owner, plus 3 years on parts. The Energy Manager has a 5-year warranty and Energy Kinetics' lifetime protection plan. Every new installation also includes our Gold Membership, with a 2-year labor warranty.
It depends on the model, venting, zones, the hot water tank and removal of the old boiler. After a free home visit we give you one written quote that covers everything.
Book a free home visit. We check your chimney, zones and hot water use and give you one written quote.
Specifications from the Energy Kinetics System 2000 brochure and EK1/EK2 oil installation manual (September 2026), checked October 2026. Energy Kinetics and System 2000 are trademarks of their owners. Product photo: Energy Kinetics.